DH-801 Series Programmable DC Electronic Load

The DH-800 Series Programmable DC Electronic Load is designed for DC power supply testing, DC-DC converter testing, battery discharge, and aging tests. Available in 120W and 400W models with input voltage ratings up to 500V, it supports Constant Current (CC), Constant Voltage (CV), Constant Resistance (CR), and Constant Power (CP) modes. Featuring precise measurements, short-circuit simulation, and intelligent cooling, it is ideal for R&D, quality control, and production testing.

  • Series :

    DH 83
  • Power (W) :

    120-400W
  • Dimension :

    190*55*130 mm
  • Operating Temperature :

    0-150V/0-500V
  • Net Weight :

    1KG
  • MOQ :

    1 Pieces
  • Delivery time :

    15 Day

The DH-800 Series programmable DC electronic loads are built for power supply testing, aging, battery discharge and general DIY debugging work. Four models cover 120W and 400W power levels with voltage ranges up to 150V or 500V, and each unit supports Constant Current (CC), Constant Voltage (CV), Constant Resistance (CR) and Constant Power (CP) operating modes with 12-bit resolution and ±(0.1% + 0.1%FS) setting accuracy.

Whether you are validating a bench supply, discharging a battery pack or running long-term burn-in, the DH-800 Series delivers stable, repeatable loading with integrated voltage, current and power measurement plus a built-in integrator for WH/AH/S tracking.

Applications

  • Power supply testing and aging fields
  • Battery discharge
  • DIY and other debugging fields

Product Parameters

Specifications Table

Parameter DH-801 (120W, 150V 20A) DH-802 (120W, 500V 5A) DH-803 (400W, 150V 30A) DH-804 (400W, 500V 10A)
Rated Range (0–40°C)        
Input Voltage 0–150V 0–500V 0–150V 0–500V
Input Current 0–20A 0–5A 0–30A 0–10A
Input Power 120W 120W 400W 400W
Load Accuracy        
Constant Current (CC) Setting Range 0–20A      
Accuracy ±(0.1% + 0.1%FS) ±(0.1% + 0.1%FS) ±(0.1% + 0.1%FS) ±(0.1% + 0.1%FS)
Resolution 10mA 10mA 10mA 10mA
Constant Voltage (CV) Setting Range 1–150V 1–500V 1–150V 1–500V
Accuracy ±(0.1% + 0.1%FS) ±(0.1% + 0.1%FS) ±(0.1% + 0.1%FS) ±(0.1% + 0.1%FS)
Resolution 100mV 100mV 100mV 100mV
Constant Resistance (CR) Mode Setting Range 0.1–999.9Ω      
Accuracy Vin/Rset*0.2% + 0.2%FS      
Resolution 12bit 12bit 12bit 12bit
Constant Power (CP) Setting Range 0–120W   0–400W  
Accuracy ±(0.2% + 0.5%FS)   ±(0.2% + 0.5%FS) ±(0.2% + 0.5%FS)
Resolution 100mW 100mW 100mW 100mW
Measurement        
Voltage Measurement 0–20A   0–30A 0–10A
Accuracy ±(0.1% + 0.1%FS) ±(0.1% + 0.1%FS) ±(0.1% + 0.1%FS) ±(0.1% + 0.1%FS)
Resolution 1mA (≤3.5A) / 10mA (>3.5A) 1mA (≤3.5A) / 10mA (>3.5A) 1mA (≤3.5A) / 10mA (>3.5A) 1mA (≤3.5A) / 10mA (>3.5A)
Voltage Measurement Range 1–150V 1–500V 1–150V 1–500V
Accuracy ±(0.1% + 0.1%FS) ±(0.1% + 0.1%FS) ±(0.1% + 0.1%FS) ±(0.1% + 0.1%FS)
Resolution 10mV (≤35V) / 100mV (>35V) 10mV (≤35V) / 100mV (>35V) 10mV (≤35V) / 100mV (>35V) 10mV (≤35V) / 100mV (>35V)
Power Measurement Range 0–120W   0–400W  
Accuracy ±(0.2% + 0.5%FS)   ±(0.2% + 0.5%FS) ±(0.2% + 0.5%FS)
Resolution 100mW 100mW 100mW 100mW
Timing Range 1S–99H59M 1S–99H59M 1S–99H59M 1S–99H59M
Max Input Voltage 155V 305V 155V 305V
Max Input Current 20.2A 5.2A 30.2A 10.2A
Dimensions & Weight 190*55*130mm, 950g 190*55*130mm, 950g 245*80*130mm, 1750g 245*80*130mm, 1750g
System Power Supply AC90–264V 50/60Hz AC90–264V 50/60Hz AC90–264V 50/60Hz AC90–264V 50/60Hz

Operating Instructions

1. Fixed Current, Current Voltage and Off Output

  1. Carefully check whether the AC input voltage is consistent with the input voltage of the product, and ensure that the connection is correct.
  2. Place the electronic load in the closed state and connect the measured source (note the positive and negative polarity).
  3. Open the rear panel switch, then the LCD is on, and the LCD screen displays the following interface (press MODE to switch):

DH-800 Series LCD interface display

  1. Select the required mode and press the encoder. At this time the voltage / current / resistance / power value of the last flicker, rotate the encoder can change, press the encoder to change the carry, no action 5S to save to the current required value, click LOAD can directly pull the load, as illustrated in the following figure:

DH-800 Series mode selection interface

DH-800 Series parameter setting interface

  1. In the case of load pulling, select the encoder to switch to display W / WH / AN / S, press the INTEGRATOR integral button to start timing and calculate WH / AH / S, and press the INTEGRATOR integration button again to stop and rotate the encoder to view the current WH / AH / S and other parameters.
  2. Press the SHORT short circuit button, can directly pull the measured source to the maximum current or the maximum current of the load; in the load case SHORT is the priority.

DH-800 Series integrator and short circuit controls

2. Fan Speed Introduction

DH-801 has the function of controlling fan speed and overtemperature protection. When the output is started, the fan starts and the air volume changes automatically with the power or current changes.

Video

In preparation, please stay tuned.

Need Help Choosing the Right DC Electronic Load?

If you can't find the right specifications to meet your needs, we will provide a customized service for different types of DC load solutions. Contact us now! Whatever and whenever you ask us, it won't cost you a penny, but an opportunity for both of us. 

Contact Us

-

 

 

Hot Tags : 120W 400W DC Electronic Load DC Electronic Load Tester Programmable DC Electronic Load
leave a message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
leave a message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
Start a Conversation

Hi! Click one of our members below to chat on